This free solution dilution calculator solves C₁V₁ = C₂V₂ for any one unknown: the volume of stock to use, the final volume, the final concentration or the required stock concentration. It converts mixed units automatically (for example mM to µM, mg/mL to µg/mL, or molar to mg/mL using the molecular weight) and gives a ready-to-follow recipe: stock volume, diluent volume, dilution factor, dilution ratio and a suitable pipette. When the stock volume is too small to pipette accurately, it proposes a stepwise (intermediate) dilution.
Solution preparation · C₁V₁ = C₂V₂
Dilution Calculator
Volume of stock to use (V₁)
V₁ = –
Enter any three values. The fourth is calculated.
How to prepare it
How to prepare it (intermediate dilution)
Dilution summary
Formula
C₁ × V₁ = C₂ × V₂
Assumes no solute is lost, gained or reacted. For accurate work, add the stock first and then make up to the final volume with diluent; volumes of some liquids (for example alcohol and water) are not exactly additive.
How to use the dilution calculator
- Choose what to find: V₁ (stock volume, the most common case), V₂ (final volume), C₂ (final concentration) or C₁ (stock concentration).
- Enter the other three values with their units. Concentration units must be of the same kind (both molar, both % v/v, both CFU/mL and so on); molar and mass units can be mixed when the molecular weight is entered.
- Read the result, the preparation steps and the dilution summary. Use Copy result for a lab notebook, Copy link to share the exact calculation, or Print for a preparation record.
The dilution formula: C₁V₁ = C₂V₂
When a solution is diluted, the amount of solute does not change; only the volume increases. The amount before dilution (C₁ × V₁) therefore equals the amount after dilution (C₂ × V₂). C₁ is the stock concentration, V₁ the volume of stock taken, C₂ the final concentration and V₂ the total final volume (stock plus diluent).
| To find | Rearranged formula | Typical question |
|---|---|---|
| Stock volume (V₁) | V₁ = C₂ × V₂ ÷ C₁ | How much stock is needed to make 100 mL of working solution? |
| Final volume (V₂) | V₂ = C₁ × V₁ ÷ C₂ | How much working solution can be made from the stock available? |
| Final concentration (C₂) | C₂ = C₁ × V₁ ÷ V₂ | What concentration results from adding 1 mL of stock to a 50 mL total? |
| Stock concentration (C₁) | C₁ = C₂ × V₂ ÷ V₁ | How concentrated must the stock be to use only 1 mL? |
Diluent to add ≈ V₂ − V₁. For accurate work the stock is measured first and the solution is then made up to the final volume (for example in a volumetric flask), because the volumes of some liquids are not exactly additive.
Dilution calculator worked examples
mg/mL dilution example
To prepare 25 mL at 0.4 mg/mL from a 10 mg/mL stock, select V₁ (stock volume) and enter those three values. Take 1.0 mL of stock (0.4 × 25 ÷ 10) and make up to 25 mL with diluent. The dilution factor is 25. If your target is written as 400 µg/mL, enter it directly in µg/mL.
ppm dilution example
To prepare 100 mL at 20 ppm from a 1,000 ppm dilute aqueous stock, enter both concentrations as ppm (mg/L). Take 2.0 mL of stock (20 × 100 ÷ 1,000) and make up to 100 mL. Use this setting when ppm can be treated as mg/L in a dilute aqueous solution. For mass-based ppm in other mixtures, use the appropriate mass basis or a density conversion.
Molarity dilution: 50 µM from a 10 mM stock
Required: 20 mL at 50 µM from a 10 mM stock. Convert to the same unit: 50 µM = 0.05 mM. V₁ = 0.05 mM × 20 mL ÷ 10 mM = 0.1 mL = 100 µL. Add diluent to 20 mL (about 19.9 mL). Dilution factor = 10 ÷ 0.05 = 200, written as a 1:200 dilution.
Percent dilution: 70% v/v isopropyl alcohol from 99% IPA
Required: 1 L of 70% v/v from 99% v/v isopropyl alcohol. V₁ = 70 × 1000 mL ÷ 99 = 707.1 mL, made up to 1 L with purified water. Alcohol–water mixtures contract slightly on mixing, so adding exactly 292.9 mL of water gives slightly less than 1 L; making up to the mark gives the correct concentration.
Serial dilution example: bacterial suspension in CFU/mL
Required: 10 mL at 1,000 CFU/mL (so that 0.1 mL carries about 100 CFU, a typical inoculum for a growth promotion test) from a suspension of 10⁸ CFU/mL. A single step would need V₁ = 1000 × 10 ÷ 10⁸ = 0.0001 mL (0.1 µL), which cannot be pipetted accurately. The calculator therefore proposes two steps:
- 0.1 mL of the 10⁸ CFU/mL suspension + 9.9 mL diluent (1:100) = 10⁶ CFU/mL.
- 10 µL of the 10⁶ CFU/mL intermediate made up to 10 mL (1:1000) = 10³ CFU/mL.
The total dilution is 1:100,000 (10⁵). Counts in a suspension are estimates, so the actual count of the final suspension is confirmed by a plate count.
Endotoxin dilution: 0.5 EU/mL from 50 EU/mL
Required: 5 mL at 0.5 EU/mL from a 50 EU/mL control standard endotoxin solution. V₁ = 0.5 × 5 ÷ 50 = 0.05 mL = 50 µL made up to 5 mL with LAL reagent water (dilution factor 100). See endotoxin units (EU) explained for how EU/mL values relate to the endotoxin limit and λ.
Dilution factor vs dilution ratio (1:10 or 1+9?)
The dilution factor is C₁ ÷ C₂, which equals V₂ ÷ V₁. In microbiology and most laboratory practice, a “1:10 dilution” means 1 part stock in 10 parts total (1 mL stock + 9 mL diluent). Some fields, however, use “1:9” or “1+9” to mean 1 part stock plus 9 parts diluent. The calculator shows both forms so that the intended meaning is clear in a procedure or record.
| Dilution factor | Written as (parts in total) | Stock + diluent | Example for 10 mL final |
|---|---|---|---|
| 2 | 1:2 | 1 + 1 | 5 mL + 5 mL |
| 10 | 1:10 | 1 + 9 | 1 mL + 9 mL |
| 100 | 1:100 | 1 + 99 | 0.1 mL + 9.9 mL |
| 1,000 | 1:1000 | 1 + 999 | 10 µL + 9.99 mL |
Units supported
| Type | Units | Notes |
|---|---|---|
| Molar | M, mM, µM, nM, pM | Converted automatically within the group |
| Mass per volume | g/L, mg/mL, mg/L, µg/mL, µg/L, ng/mL, % w/v, ppm | 1% w/v = 1 g/100 mL = 10 g/L; ppm treated as mg/L (dilute aqueous solutions) |
| Molar ↔ mass | Any molar with any mass unit | Requires the molecular (formula) weight in g/mol |
| Percent volume | % v/v | For alcohols and other liquids; make up to volume |
| Fold | × (10×, 1×) | For concentrated buffers and media supplements |
| Per mL | CFU/mL, EU/mL, IU/mL, U/mL, cells/mL | C₁ and C₂ must use the same unit |
Large counts can be typed as 1.5e8, 1.5×10^8 or 10^8.
Common dilution mistakes
- Using V₂ as the diluent volume. V₂ is the total final volume; the diluent is about V₂ − V₁.
- Mixing units. 10 mM and 50 µM cannot be divided directly; both must be in the same unit first.
- Swapping C₁ and C₂. If the final concentration is higher than the stock, the result is a concentration, not a dilution, and the calculator flags it.
- Pipetting very small volumes. Volumes below about 10 µL carry larger relative errors; an intermediate dilution is more accurate.
- Misreading 1:10. State whether a ratio means parts in total or stock + diluent.
- Adding water to a fixed volume of alcohol. Alcohol–water mixtures contract; make up to the final volume instead.
Dilution ratio, percent, mg/mL and alcohol dilutions
Dilution ratio (1:X)
For a 1:X dilution (1 part stock in X parts total), the stock volume is V₁ = V₂ ÷ X and the diluent is V₂ − V₁. Example: 1:20 to make 100 mL = 5 mL stock + 95 mL diluent. In the calculator, select the × unit and enter C₁ = X and C₂ = 1, or enter the real concentrations; the result shows the ratio both as 1:X and as stock + diluent (1 + X−1).
Percent dilution (% v/v and % w/v)
Percent solutions dilute with the same formula: V₁ = %₂ × V₂ ÷ %₁. Example: 0.5% w/v from a 5% w/v stock for 200 mL = 20 mL stock made up to 200 mL. Select % v/v for liquids (alcohols, disinfectants) and % w/v for dissolved solids.
mg/mL, µg/mL and molar dilutions
Mass concentrations (mg/mL, µg/mL, ng/mL, mg/L) and molar concentrations (M, mM, µM, nM) are converted automatically, so C₁ and C₂ can be entered in different units of the same kind. To go between molar and mg/mL, enter the molecular weight when the calculator asks for it.
Alcohol dilution (70% IPA or ethanol)
To make 70% v/v alcohol from a 95% or 99% stock: V₁ = 70 × V₂ ÷ stock %. For 1 L from 95% ethanol, measure 736.8 mL and make up to 1 L with purified water; from 99% isopropyl alcohol, 707.1 mL. Alcohol and water contract when mixed, so make up to the final volume instead of adding a calculated volume of water.
Frequently Asked Questions (FAQs)
How do you calculate a dilution ratio?
Divide the final volume by the dilution factor to get the stock volume. A 1:10 dilution of 50 mL needs 5 mL of stock + 45 mL of diluent; a 1:4 dilution (1 part in 4 total) of 20 mL needs 5 mL + 15 mL. If a procedure writes 1:4 to mean 1 part + 4 parts, the total is 5 parts, so check which convention is used.
What does C₁V₁ = C₂V₂ mean?
It states that the amount of solute in the stock taken (concentration × volume) equals the amount in the final diluted solution. Any one of the four values can be calculated when the other three are known.
How much diluent should be added?
Approximately V₂ − V₁. For accurate work, measure V₁ of stock and then add diluent up to the final volume V₂ rather than adding a calculated volume of diluent.
How is the dilution factor calculated?
Dilution factor = C₁ ÷ C₂ = V₂ ÷ V₁. For example, 1 mL of stock made up to 100 mL is a dilution factor of 100 (a 1:100 dilution). In a series, the individual factors are multiplied: 1:10 followed by 1:100 gives 1:1000.
Can different units be used for C₁ and C₂?
Yes, within the same type of unit (for example mM and µM, or mg/mL and µg/mL). Molar and mass concentrations can also be combined when the molecular weight is entered. Units of different kinds, such as % v/v and CFU/mL, cannot be converted into each other.
When should a serial or intermediate dilution be used?
When the stock volume from a single step is too small to measure accurately (below about 10 µL) or the dilution factor is very large, as with bacterial suspensions. Stepwise 1:10 or 1:100 dilutions keep each transfer in an accurate pipetting range.
Does C₁V₁ = C₂V₂ apply to CFU/mL and EU/mL?
Yes. The relationship holds for any quantity per volume, including colony-forming units and endotoxin units, provided nothing is lost or gained during dilution. For microbial suspensions, the actual count is confirmed by plating because counts are estimates.
Related tools and guides
- All free microbiology calculators
- Maximum Valid Dilution (MVD) calculator for the bacterial endotoxins test
- Growth promotion test of culture media
- Microbial limit test (USP <61> and <62>)
- Endotoxin units (EU) explained
After a dilution series is plated, colony counts are converted back to CFU/mL or CFU/g using the formula explained in Total Viable Count (TVC): Plate Count Method, Formula and Calculation.