Calculate the endotoxin limit of a parenteral product from its maximum dose using EL = K/M, the general formula in USP General Chapter <85>. The calculator covers non-intrathecal and intrathecal products, dosing per body surface area, and radiopharmaceuticals (175/V and 14/V), and gives the limit in EU/mg, EU/mL or EU/Unit.
Bacterial endotoxins test · USP <85> formula
Endotoxin Limit Calculator (K/M)
Endotoxin limit
EL = –
Choose the product and route, then enter the maximum dose.
Formula
EL = KM
Step-by-step
If the product monograph or your approved specification states an endotoxin limit, that limit applies. Where a product can be given by more than one route or dosing regimen, calculate each and use the lowest limit.
Learn how the endotoxin limit is calculated
Want to check the reasoning behind the result? Our guide Endotoxin Limit Calculation (K/M): Formula, K Values and Worked Examples explains K and M, how to handle infusions and per-patient doses, worked examples for each product type, common mistakes and frequently asked questions.
- Endotoxin limit formula and worked examples
- Next step: MVD Calculator
- Maximum valid dilution (MVD) explained
- What bacterial endotoxins are and how they are tested
This calculator is an educational tool. It is not approved or endorsed by USP or any regulator. Always verify results against your approved specifications, the current pharmacopoeial text and your validated laboratory procedures.