Calculate the maximum valid dilution (MVD) for the bacterial endotoxins test (BET) from your endotoxin limit, the concentration of the sample solution and the lysate sensitivity (λ). The calculator uses the general MVD equation in USP General Chapter <85> and handles EU/mg, EU/mL and EU/Unit limits with automatic unit conversion.
Bacterial endotoxins test · USP <85> formula
MVD Calculator
Maximum Valid Dilution
MVD = –
Enter the endotoxin limit, concentration and λ.
Formula
MVD = EL × Cλ
Step-by-step
Your test dilution must not exceed the calculated MVD, and it must be shown suitable (inhibition/enhancement testing) for the BET method used.
Learn how MVD is calculated
New to MVD, or want to check the reasoning behind the result? Our guide Maximum Valid Dilution (MVD) in BET: Formula and Worked Example explains the formula, which concentration and λ to use, a step-by-step example, common calculation mistakes, how MVD relates to method suitability, and answers to frequently asked questions.
- MVD formula and worked example
- What bacterial endotoxins are and how they are tested
- Lysate sensitivity confirmation for the gel-clot test
This calculator is an educational tool. It is not approved or endorsed by USP or any regulator. Always verify results against your approved specifications, the current pharmacopoeial text and your validated laboratory procedures.