ISO 14644-1 is the international standard that classifies cleanrooms and clean zones by the concentration of airborne particles. It defines nine classes, from ISO Class 1 (cleanest) to ISO Class 9, and sets out how a room is tested to prove its class. This guide covers only the ISO system. For how ISO classes relate to the pharmaceutical Grades A, B, C and D, see cleanroom grades A, B, C and D vs ISO classes.
ISO 14644-1 at a glance
| Item | Requirement |
|---|---|
| Current edition | ISO 14644-1:2015, Classification of air cleanliness by particle concentration |
| What is classified | Airborne particle concentration only (particles per m³ at stated sizes from 0.1 µm to 5 µm) |
| Classes | ISO Class 1 to ISO Class 9; intermediate classes in steps of 0.1 are allowed |
| Occupancy states | As-built, at-rest or operational (must be stated) |
| Number of sampling locations | From the room area, Table A.1 (for example 6 locations for 12 m²) |
| Minimum sample volume | Vs = (20 ÷ Cn,m) × 1,000 litres, at least 2 L and at least 1 minute per location |
| Pass criterion | The average concentration at every location must not exceed the class limit for each considered size |
| Retest interval (ISO 14644-2:2015) | 6 months for ISO 5 and cleaner; 12 months for classes above ISO 5 |
ISO cleanroom classes 1 to 9
Each class sets the maximum number of particles per cubic metre equal to or larger than each considered size. The figures are cumulative: the ≥0.3 µm limit for ISO Class 5 counts every particle of 0.3 µm and above.
| ISO class | ≥0.1 µm | ≥0.2 µm | ≥0.3 µm | ≥0.5 µm | ≥1 µm | ≥5 µm |
|---|---|---|---|---|---|---|
| ISO 1 | 10 | – | – | – | – | – |
| ISO 2 | 100 | 24 | 10 | – | – | – |
| ISO 3 | 1,000 | 237 | 102 | 35 | – | – |
| ISO 4 | 10,000 | 2,370 | 1,020 | 352 | 83 | – |
| ISO 5 | 100,000 | 23,700 | 10,200 | 3,520 | 832 | – |
| ISO 6 | 1,000,000 | 237,000 | 102,000 | 35,200 | 8,320 | 293 |
| ISO 7 | – | – | – | 352,000 | 83,200 | 2,930 |
| ISO 8 | – | – | – | 3,520,000 | 832,000 | 29,300 |
| ISO 9 | – | – | – | 35,200,000 | 8,320,000 | 293,000 |
Points that are often misreported:
- ISO Class 5 has no ≥5 µm limit. The 1999 edition listed 29 particles/m³; the 2015 edition removed it. Where a ≥5 µm limit is needed, it comes from another requirement, such as EU GMP Annex 1 for Grade A, or from the macroparticle (M) descriptor.
- ISO classes do not cover microorganisms. Microbial limits come from GMP guidance, such as EU GMP Annex 1 or the FDA aseptic processing guidance.
- “ISO 7” on its own is incomplete. The occupancy state and particle sizes must be stated.
The ISO 14644-1 class formula
The class limits in the table come from one formula:
Cn = 10N × (0.1 ÷ D)2.08
- Cn = maximum permitted concentration (particles/m³) of particles equal to or larger than size D
- N = ISO class number (not more than 9; intermediate values in steps of 0.1 are allowed)
- D = considered particle size in µm
- 0.1 = a constant, in µm
Example for ISO Class 7 at ≥0.5 µm: 107 × (0.1 ÷ 0.5)2.08 = 107 × 0.0352 = 352,000 particles/m³, which matches the table.
Occupancy states
| State | Meaning |
|---|---|
| As-built | The installation is complete and working, with all services connected, but there is no production equipment, materials or personnel |
| At-rest | The installation is complete with equipment installed and operating as agreed, but no personnel are present |
| Operational | The installation is working in the agreed manner, with the specified number of personnel present |
A classification is written with the class, state and sizes, for example: ISO Class 5; at-rest; 0.3 µm and 0.5 µm.
How to perform ISO 14644-1 cleanroom classification
- Agree the target. Set the ISO class, the occupancy state and the particle sizes to be considered.
- Find the minimum number of sampling locations. Use Table A.1 with the room area, or the ISO 14644 sampling location calculator. For areas above 1,000 m², NL = 27 × (A ÷ 1,000), rounded up.
- Place the locations. Divide the room into as many sections of equal area as there are locations, and put one location in each section at a representative point, usually at work height.
- Calculate the sample volume. Vs = (20 ÷ Cn,m) × 1,000 litres, where Cn,m is the class limit for the largest considered size. Sample at least 2 L and for at least 1 minute at each location.
- Use a calibrated particle counter (calibrated to ISO 21501-4) with a short sample tube.
- Measure and average. Record the counts at each location and calculate the average concentration for each considered size.
- Evaluate. The room or zone passes only if the average at every location is within the class limit for every considered size.
- Report. Include the class designation, occupancy state, sizes, location map, sample volumes, counter details and results.
Minimum number of sampling locations (Table A.1, extract)
| Room area up to (m²) | Locations |
|---|---|
| 2 | 1 |
| 4 | 2 |
| 6 | 3 |
| 8 | 4 |
| 10 | 5 |
| 24 | 6 |
| 28 | 7 |
| 32 | 8 |
| 36 | 9 |
| 52 | 10 |
| 56 | 11 |
| 64 | 12 |
| 68 | 13 |
| 72 | 14 |
| 76 | 15 |
| 104 | 16 |
Worked example: 30 m² room, ISO 7, at-rest, 0.5 µm and 5 µm
- Locations: 30 m² is not more than 32 m², so NL = 8.
- Sample volume at ≥0.5 µm: (20 ÷ 352,000) × 1,000 = 0.057 L, so the 2 L minimum applies.
- Sample volume at ≥5 µm (the largest size, which decides): (20 ÷ 2,930) × 1,000 = 6.83 L.
- With a 28.3 L/min counter: 6.83 ÷ 28.3 = 0.24 min, so the 1-minute minimum applies and each location is sampled for 1 minute (28.3 L).
- Result: every one of the 8 location averages must be within 352,000 particles/m³ at ≥0.5 µm and 2,930 particles/m³ at ≥5 µm.
When Vs is very large (very clean classes at small sizes), the standard allows a sequential sampling procedure to reduce sampling time.
What changed in the 2015 edition
- The square-root formula for sampling locations was replaced by Table A.1, which gives 95% confidence that at least 90% of the area does not exceed the class limit.
- The 95% upper confidence limit (UCL) calculation was removed; each location is evaluated on its own.
- Limits were removed for some class and size combinations, including ISO Class 5 at ≥5 µm.
- Macroparticle counting (the M descriptor) was revised.
How often is cleanroom classification repeated?
ISO 14644-2:2015 sets the maximum interval between particle concentration tests for classification:
| Class | Maximum interval |
|---|---|
| ISO Class 5 and cleaner | 6 months (average not more than 183 days, no interval over 190 days) |
| Classes above ISO 5 | 12 months (average not more than 366 days, no interval over 400 days) |
Between classifications, rooms are monitored to a risk-based monitoring plan, and a room is reclassified after any change that could affect its performance.
ISO classes vs Federal Standard 209E
The US Federal Standard 209E was withdrawn in 2001, but its class names are still heard. Its classes were based on particles ≥0.5 µm per cubic foot.
| FS 209E class | ISO 14644-1 equivalent |
|---|---|
| Class 1 | ISO 3 |
| Class 10 | ISO 4 |
| Class 100 | ISO 5 |
| Class 1,000 | ISO 6 |
| Class 10,000 | ISO 7 |
| Class 100,000 | ISO 8 |
ISO classes in pharmaceutical manufacturing
Sterile manufacturing works mainly in ISO 5, 7 and 8 conditions. EU GMP Annex 1 classifies Grade A as ISO 5, Grade B as ISO 5 at rest and ISO 7 in operation, Grade C as ISO 7 at rest and ISO 8 in operation, and Grade D as ISO 8 at rest. GMP grades also add microbial limits, gowning and monitoring rules; see cleanroom grades A, B, C and D vs ISO classes.
Frequently Asked Questions (FAQs)
How many ISO cleanroom classes are there?
Nine: ISO Class 1 to ISO Class 9. ISO Class 1 is the cleanest, and ISO Class 9 applies to the operational state only. Intermediate classes in steps of 0.1 can also be specified.
What is an ISO Class 1 cleanroom?
The cleanest class in ISO 14644-1:2015, allowing at most 10 particles per m³ of 0.1 µm and larger. It is used in fields such as semiconductor and nanotechnology manufacturing, not in pharmaceutical production.
What is an ISO Class 5 cleanroom?
A room or zone with not more than 3,520 particles/m³ of 0.5 µm and larger (and 832 at ≥1 µm, 10,200 at ≥0.3 µm). In pharmaceuticals, ISO 5 is the level for Grade A critical zones.
What is the difference between ISO 7 and ISO 8?
ISO 7 allows not more than 352,000 particles/m³ at ≥0.5 µm; ISO 8 allows 3,520,000, ten times more. Each class step changes the limit by a factor of ten.
How does ISO cleanroom classification work?
Particles are counted at a minimum number of locations set by the room area, with enough air sampled at each location, and the average at every location must be within the class limit at the chosen sizes and occupancy state. The ISO 14644 sampling location calculator gives the number of locations and the sample volume rule.
Does ISO 14644-1 set microbial limits?
No. It covers airborne particles only. Microbial limits for pharmaceutical cleanrooms come from GMP guidance such as EU GMP Annex 1 and the FDA aseptic processing guidance.
References
- ISO 14644-1:2015, Cleanrooms and associated controlled environments – Part 1: Classification of air cleanliness by particle concentration.
- ISO 14644-2:2015, Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration.
- European Commission, EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products (2022).
- U.S. FDA, Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice (2004).
This guide summarises the standards for education. Use the current official editions and your approved procedures for testing.
Noman Iftikhar is a microbiologist with an MPhil in Microbiology and professional experience in pharmaceutical microbiology. His work includes sterility testing, bacterial endotoxin testing, microbial limit testing, environmental monitoring, and microbiological quality control. Through MicrobiologyPedia, he shares practical, evidence-based guidance to help microbiology students and laboratory professionals understand testing procedures, laboratory practices, and quality standards.