Last updated: 14 November 2026
A non viable particle count is the number of airborne particles, at or above a stated size, measured in a known volume of cleanroom air. In pharmaceutical manufacturing the reported sizes are ≥0.5 µm and ≥5.0 µm, and results are expressed as particles per cubic metre (particles/m³). The count is used for two different jobs: classifying a cleanroom against ISO 14644-1 or the EU/PIC/S GMP grade tables, and routinely monitoring it during manufacturing against GMP alert and action limits.
This page covers both, keeps ISO and GMP requirements separate, and shows the calculations used for sample locations and sample volume.
What is non-viable particle counting?
Non-viable particle counting measures total airborne particles without telling you whether they are alive. Skin flakes, fibres from garments, droplets, metal and plastic fragments from machinery and microorganisms all register as particles. The current EU GMP Annex 1 therefore uses the term total particle monitoring rather than “non-viable”.
The count matters because airborne particles are the vehicle for most microbial contamination in aseptic areas, and they respond within seconds to a failed HEPA filter, a disturbed airflow pattern or poor operator technique. A viable air sample takes days to give a result; a particle counter shows a problem in real time.
What is a non-viable particle counter?
A non-viable particle counter is an optical particle counter (OPC) that draws a measured flow of air and counts and sizes the particles in it. Pharmaceutical cleanrooms use three formats:
- Portable counters on a trolley or handheld, used for classification, requalification and routine checks in Grade C and D areas.
- Remote (installed) sensors that sample continuously at fixed points and report to a facility monitoring system. These are the usual choice for Grade A and B.
- Manifold systems, where one counter samples several points in sequence through tubing. Long tubing lowers recovery of ≥5.0 µm particles, so these need careful design.
For GMP work the counter should have at least the ≥0.5 µm and ≥5.0 µm channels, a flow rate of 28.3 L/min (1 ft³/min) or more, and calibration traceable to ISO 21501-4.
How does an airborne particle counter work?
The counter pulls air through an inlet at a controlled flow rate into a sensing chamber. A laser beam crosses the airstream; each particle passing through it scatters a pulse of light onto a photodetector. The number of pulses gives the count, and the height of each pulse, compared with calibration curves made with polystyrene latex spheres of known size, assigns the particle to a size channel. The air then exits through a HEPA filter on the exhaust.
Two practical points follow from this design. First, the “size” is an optical equivalent diameter, not a physical one, so irregular fibres may size differently from spheres. Second, at very high concentrations two particles can be in the beam at once and be counted as one larger particle (coincidence loss). Every counter has a stated maximum concentration; dirty Grade D areas or aerosol-generating steps can exceed it.
Viable vs non-viable particle monitoring
| Feature | Total (non-viable) particles | Viable particles |
|---|---|---|
| What is measured | All particles ≥0.5 µm and ≥5.0 µm | Microorganisms that grow on culture media |
| Units | particles/m³ | CFU/m³, CFU/plate, CFU/glove |
| Methods | Optical particle counter | Active air sampler, settle plates, contact plates, glove prints |
| Time to result | Real time | Days (after incubation) |
| Annex 1 limit table | Table 5 (monitoring) | Table 6 (monitoring) |
| Main use | Detect HVAC, airflow and intervention problems immediately | Demonstrate microbial control of the area and personnel |
Neither method replaces the other. A low particle count does not prove an area is free of microorganisms, and a single CFU in Grade A must be investigated regardless of the particle data. For the full monitoring programme, including viable methods, see environmental monitoring in pharmaceutical cleanrooms.
ISO 14644-1, EU GMP and PIC/S GMP particle limits
These documents do different jobs. ISO 14644-1:2015 is a classification standard: it defines ISO Classes 1 to 9 by maximum particle concentration and gives the test method. EU GMP Annex 1 and the PIC/S GMP Guide define pharmaceutical Grades A to D, with separate limits for “at rest” and “in operation”. PIC/S adopted the same revised Annex 1 as the EU, with only minor editorial differences, effective 25 August 2023; the current PIC/S guide edition is PE 009-18.
ISO 14644-1:2015 class limits (≥0.5 µm and ≥5.0 µm)
| ISO class | ≥0.5 µm (particles/m³) | ≥5.0 µm (particles/m³) | Typical pharma use |
|---|---|---|---|
| ISO 5 | 3,520 | 29* | Grade A; Grade B at rest |
| ISO 6 | 35,200 | 293 | Occasionally used as a transition zone |
| ISO 7 | 352,000 | 2,930 | Grade B in operation; Grade C at rest |
| ISO 8 | 3,520,000 | 29,300 | Grade C in operation; Grade D at rest |
| ISO 9 | 35,200,000 | 293,000 | Rare in pharma |
*ISO 14644-1 adds a note that ≥5.0 µm classification at ISO 5 is limited by sampling statistics. The class limits come from the formula Cn = 10N × (0.1/D)2.08, where N is the ISO class number and D the particle size in µm. For a full explanation see ISO 14644-1 cleanroom classification and cleanroom grades vs ISO classes.
EU GMP / PIC/S Annex 1 classification limits (Table 1)
| Grade | ≥0.5 µm at rest | ≥0.5 µm in operation | ≥5.0 µm at rest | ≥5.0 µm in operation |
|---|---|---|---|---|
| A | 3,520 | 3,520 | Not specified | Not specified |
| B | 3,520 | 352,000 | Not specified | 2,930 |
| C | 352,000 | 3,520,000 | 2,930 | 29,300 |
| D | 3,520,000 | Not predetermined | 29,300 | Not predetermined |
Annex 1 allows ≥5.0 µm particles to be included in classification where the contamination control strategy (CCS) or historical trends indicate it. For Grade D in operation, the manufacturer sets the limit based on risk.
US FDA aseptic processing guidance (2004)
For comparison, the FDA guidance classifies by the ≥0.5 µm size only, measured in operation: Class 100 (ISO 5) 3,520; Class 10,000 (ISO 7) 352,000; Class 100,000 (ISO 8) 3,520,000 particles/m³. It has no at-rest/in-operation split and no ≥5.0 µm limit.
EU GMP Annex 1 particle monitoring requirements
Classification proves a room can reach a grade. Monitoring proves it stays there during production. Annex 1 sets separate monitoring limits in Table 5, and these act as the maximum (action) limits.
| Grade | ≥0.5 µm at rest | ≥0.5 µm in operation | ≥5.0 µm at rest | ≥5.0 µm in operation |
|---|---|---|---|---|
| A | 3,520 | 3,520 | 29 | 29 |
| B | 3,520 | 352,000 | 29 | 2,930 |
| C | 352,000 | 3,520,000 | 2,930 | 29,300 |
| D | 3,520,000 | Not predetermined | 29,300 | Not predetermined |
Note the difference from Table 1: ≥5.0 µm particles are monitored in Grade A and B even though they are not used to classify Grade A. Large particles are an early signal of a breach, such as an operator intervention or equipment wear. Annex 1 accepts that an occasional isolated ≥5.0 µm count in Grade A may be a false count, but consecutive or regular low-level counts may indicate a contamination event and must be investigated.
The main Annex 1 monitoring expectations are:
- Grade A: continuous monitoring of ≥0.5 µm and ≥5.0 µm for the full duration of critical processing, including equipment assembly, at a sample flow rate of at least 28 L/min, so that interventions and transient events are captured.
- Grade B: a similar system is recommended; frequency and sample size must be sufficient to detect increases in contamination and system deterioration.
- Grade C and D: monitoring set by quality risk management and the CCS.
- Alert levels must be set for all grades (Grade A total particles only for alerts) to detect adverse trends before action limits are reached.
- Remote systems must take account of tubing length and bend radius, because both reduce recovery of large particles.
Pharmaceutical cleanroom monitoring procedure
The procedure below is a typical framework for routine monitoring with a portable counter. Your SOP must follow your own CCS and qualification data.
- Check the counter. Confirm the calibration is in date, run a zero-count check with the purge (HEPA) filter fitted, and confirm the flow rate.
- Prepare and transfer. Disinfect the counter and probe before taking it into the area, following your material-transfer procedure.
- Position the probe. Place the inlet at the defined location, at working height, facing into the airflow. In unidirectional airflow use an isokinetic probe.
- Set the sample. Enter the location ID, sample volume and occupancy state (at rest or in operation).
- Sample without disturbing. Keep the operator downstream of the probe and out of first air.
- Record and compare. Record ≥0.5 µm and ≥5.0 µm counts per m³ and compare them with the alert and action limits for that grade and occupancy state.
- Respond to excursions. Repeat only if the procedure allows it, notify QA, and open a deviation or investigation for any action-limit excursion.
- Trend the data monthly or more often, by location and by shift.
Sampling locations and sampling volume
Number of sampling locations (classification)
ISO 14644-1:2015 Annex A links the minimum number of locations to the room’s floor area. Selected values from Table A.1:
| Area up to (m²) | Minimum locations | Area up to (m²) | Minimum locations |
|---|---|---|---|
| 2 | 1 | 36 | 9 |
| 4 | 2 | 52 | 10 |
| 6 | 3 | 76 | 15 |
| 8 | 4 | 104 | 16 |
| 10 | 5 | 156 | 20 |
| 24 | 6 | 276 | 23 |
| 28 | 7 | 436 | 25 |
| 32 | 8 | 1,000 | 27 |
Example: a 30 m² Grade C room needs at least 8 classification locations (30 m² is above 28 and up to 32 m²). The room is divided into 8 equal sections and one location placed in each. Above 1,000 m², NL = 27 × (A/1,000), rounded up. You can check any room size with the ISO 14644 sampling location calculator.
Routine monitoring locations are not set by this table. Annex 1 expects them to be chosen by a documented risk assessment, using classification results, airflow visualisation (smoke studies) and the positions of open product and interventions.
Minimum sample volume
ISO 14644-1 sets the minimum single-sample volume so that at least 20 particles would be expected if the concentration were at the class limit:
Vs = (20 / Cn,m) × 1,000 (litres), where Cn,m is the class limit (particles/m³) for the largest particle size considered. Each sample must be at least 2 L and at least 1 minute long.
| Case | Class limit (Cn,m) | Minimum volume | Run time at 28.3 L/min (1 CFM) | Run time at 100 L/min |
|---|---|---|---|---|
| Grade A / ISO 5, ≥0.5 µm | 3,520 /m³ | 5.68 L → 1-minute rule governs | 1 min (28.3 L) | 1 min (100 L) |
| ISO 5, ≥5.0 µm included | 29 /m³ | 689.66 L | 24.37 min → 25 min (707.5 L) | 6.90 min → 7 min (700 L) |
| ISO 4, ≥1.0 µm | 83 /m³ | 240.96 L | 8.51 min → 9 min (254.7 L) | 2.41 min → 3 min (300 L) |
| ISO 6, ≥5.0 µm | 293 /m³ | 68.26 L | 2.41 min → 3 min (84.9 L) | 0.68 min → 1 min (100 L) |
| Grade C at rest / ISO 7, ≥5.0 µm | 2,930 /m³ | 6.83 L → 1-minute rule governs | 1 min (28.3 L) | 1 min (100 L) |
| Grade D at rest / ISO 8, ≥5.0 µm | 29,300 /m³ | 0.68 L → 2 L and 1-minute rules govern | 1 min (28.3 L) | 1 min (100 L) |
Worked example (Grade A with ≥5.0 µm, 100 L/min counter): Vs = (20 / 29) × 1,000 = 689.66 L. Time = 689.66 ÷ 100 = 6.90 min. Counters are set in whole minutes, so round up to 7 minutes, which collects 700 L and meets the minimum. Rounding down to 6 minutes (600 L) would fail the requirement. With a 1 CFM counter the same sample needs 689.66 ÷ 28.3 = 24.37 min, so set 25 minutes.
Try your own class, particle sizes and flow rate below, or open the full ISO 14644-1 sample volume calculator:
How many locations? That depends on the room area. Use the ISO 14644 sampling location calculator.
Method: ISO 14644-1:2015, Annex A. Vs = (20 / Cn,m) × 1000 L; each sample at least 2 L and at least 1 minute. Class limits from Table 1; intermediate classes from Cn = 10N × (0.1/D)2.08, rounded to 3 significant figures. Use for planning; your SOP and the standard text govern.
Monitoring frequency and alert/action limits
| Activity | Requirement or typical practice | Source |
|---|---|---|
| Grade A monitoring | Continuous throughout critical processing, including assembly | EU/PIC/S Annex 1 |
| Grade B monitoring | Similar system recommended; frequency may be lower but must detect deterioration | EU/PIC/S Annex 1 |
| Grade C and D monitoring | Risk-based frequency; often per shift or daily for C, weekly for D (industry practice) | Annex 1 (QRM); site CCS |
| Requalification (classification) | Grade A and B at least every 6 months; Grade C and D at least every 12 months | EU/PIC/S Annex 1 |
| Periodic particle testing (non-GMP or general) | ISO 5 and cleaner: maximum interval 6 months; ISO 6 to 9: 12 months | ISO 14644-2:2015 |
Action limits are the Annex 1 Table 5 values (or tighter values in your CCS). Alert levels are set by the site, usually from historical data, for example the 95th or 99th percentile of 6–12 months of results for each location. They must be below the action limit and reviewed periodically. Annex 1 also expects alerts to trigger on trends, such as several consecutive results above normal, not only on single values.
When an action limit is exceeded, the investigation should cover what was happening at the time (interventions, door openings, personnel movement), HVAC and pressure data, counter performance, and the potential impact on product made in that period.
Calibration and qualification of particle counters
Airborne particle counters used for cleanroom classification and GMP monitoring should be calibrated to ISO 21501-4:2018. The calibration covers:
- size setting with certified polystyrene latex (PSL) spheres;
- counting efficiency (about 50% at the minimum detectable size and about 100% at 1.5 to 2 times that size);
- size resolution;
- false count rate (zero count);
- sample flow rate accuracy.
Annual calibration is the common interval, and the calibration certificate should state ISO 21501-4 conformity.
Calibration alone is not qualification. Installed GMP systems also need IQ, OQ and PQ, including:
- alarm and data-integrity testing (audit trail, time synchronisation and user access, in line with EU GMP Annex 11);
- verification of transport losses in remote tubing;
- for remote sensors, confirmation that the sample point represents the critical zone.
Common mistakes
- Using classification limits as monitoring limits. Grade A has no ≥5.0 µm classification limit but does have a ≥5.0 µm monitoring limit of 29/m³.
- Calling Grade A “ISO 5” for every purpose. The ≥0.5 µm limits match, but GMP adds at-rest/in-operation states, continuous monitoring and microbial limits.
- Undersized samples when ≥5.0 µm is included in ISO 5 classification (a 1-minute sample is not enough).
- Long or coiled tubing on manifold or remote systems, which loses large particles.
- Sampling from an operator-shadowed position or with the probe facing away from the airflow.
- Setting alert levels once and never reviewing them, or setting them so high that no trend is ever detected.
- Treating a 5 µm count as “probably false” without checking for a pattern.
FAQs
What is the difference between viable and non-viable particle count?
A non-viable (total) particle count measures all airborne particles with an optical counter in real time. A viable count measures only microorganisms that grow on culture media, reported as CFU after incubation. Both are required in GMP cleanrooms.
What is the non-viable particle count limit for Grade A?
3,520 particles/m³ at ≥0.5 µm, at rest and in operation. For monitoring, Annex 1 Table 5 also sets 29 particles/m³ at ≥5.0 µm.
How do you calculate particle count per cubic metre?
Divide the counted particles by the sampled volume in m³. For example, 85 particles ≥0.5 µm in 28.3 L (0.0283 m³) = 85 / 0.0283 = 3,004 particles/m³.
Is ISO 5 the same as Grade A?
Not exactly. Grade A meets ISO 5 for ≥0.5 µm particles, but Annex 1 adds in-operation requirements, continuous monitoring, ≥5.0 µm monitoring limits and microbial limits.
How often should a particle counter be calibrated?
Typically once a year to ISO 21501-4, and after any repair that affects the optics, flow or electronics.
References
- European Commission. EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products. C(2022) 5938 final, 22 August 2022; in operation from 25 August 2023.
- PIC/S. Guide to Good Manufacturing Practice for Medicinal Products, Annex 1. PE 009 (revised Annex 1 effective 25 August 2023; current edition PE 009-18, 2026).
- ISO 14644-1:2015. Cleanrooms and associated controlled environments, Part 1: Classification of air cleanliness by particle concentration.
- ISO 14644-2:2015. Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration.
- ISO 21501-4:2018. Determination of particle size distribution, single particle light interaction methods, Part 4: Light scattering airborne particle counter for clean spaces.
- US FDA. Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing, Current Good Manufacturing Practice (2004).
- Health Canada. Annex 1 to the GMP guide (GUI-0119): Environmental and process monitoring.
Noman Iftikhar is a microbiologist with an MPhil in Microbiology and professional experience in pharmaceutical microbiology. His work includes sterility testing, bacterial endotoxin testing, microbial limit testing, environmental monitoring, and microbiological quality control. Through MicrobiologyPedia, he shares practical, evidence-based guidance to help microbiology students and laboratory professionals understand testing procedures, laboratory practices, and quality standards.